<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Humidity &amp; Temperature Sensors | Sensors &amp; Electronic Components - DuoMy</title>
	<atom:link href="https://www.duomy.com/product-category/humidity-temperature-sensors/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.duomy.com/product-category/humidity-temperature-sensors/</link>
	<description></description>
	<lastBuildDate>Fri, 20 Nov 2026 01:06:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://www.duomy.com/wp-content/uploads/2026/04/cropped-电子-32x32.png</url>
	<title>Humidity &amp; Temperature Sensors | Sensors &amp; Electronic Components - DuoMy</title>
	<link>https://www.duomy.com/product-category/humidity-temperature-sensors/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Humidity &#038; Temperature Sensor with PTFE Filter, ±3% RH</title>
		<link>https://www.duomy.com/products/rh-t-sensor-ptfe-filter/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:42 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/rh-t-sensor-ptfe-filter/</guid>

					<description><![CDATA[<p>Digital humidity and temperature sensor with an integrated PTFE membrane filter, ±3% RH, I²C, 2.4 to 5.5 V. For dusty, dirty and condensing environments where an open sensor port would clog.</p>
<p>The post <a href="https://www.duomy.com/products/rh-t-sensor-ptfe-filter/">Humidity &#038; Temperature Sensor with PTFE Filter, ±3% RH</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>The sensing element in any capacitive humidity sensor is a polymer layer that must be exposed to the air. In a flour mill or a spray booth, that exposure also means dust and oil, and the sensor drifts until it reads the contamination rather than the humidity. A PTFE membrane passes water vapour but blocks particles and liquid water.</p>
<p>The cost is response time: twelve seconds instead of eight. For room monitoring and drying processes that is irrelevant; for a fast humidity cycle it matters, and the unfiltered part is the right choice with a mechanical shroud instead.</p>
<h2>Key features</h2>
<ul>
<li>Integrated PTFE membrane filter, IP67 rated</li>
<li>Blocks dust, oil mist and liquid water</li>
<li>±3% RH and ±0.3 °C</li>
<li>I²C interface, 16-bit calibrated output</li>
<li>Same footprint as the unfiltered variant</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Dusty production and storage areas</li>
<li>Food processing and bakeries</li>
<li>Condensing environments</li>
<li>Outdoor equipment housings</li>
</ul>
<h2>Selection note</h2>
<p>Do not clean the membrane with solvent or compressed air. Both force contamination into the polymer layer, and the sensor cannot be recovered once that happens.</p>
<h2>Ordering</h2>
<p>Send the environment, contamination risk and required response time. We confirm whether the filtered or unfiltered variant fits, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/rh-t-sensor-ptfe-filter/">Humidity &#038; Temperature Sensor with PTFE Filter, ±3% RH</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>High-Accuracy Humidity &#038; Temperature Sensor, ±1.5% RH</title>
		<link>https://www.duomy.com/products/high-accuracy-rh-t-sensor-15pct/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/high-accuracy-rh-t-sensor-15pct/</guid>

					<description><![CDATA[<p>High-accuracy digital humidity and temperature sensor, ±1.5% RH and ±0.1 °C, I²C and SPI interfaces, 1.62 to 3.6 V supply. For calibration-critical and regulated environments.</p>
<p>The post <a href="https://www.duomy.com/products/high-accuracy-rh-t-sensor-15pct/">High-Accuracy Humidity &#038; Temperature Sensor, ±1.5% RH</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>Half a percent of RH and a tenth of a degree is the accuracy class that regulated storage and cleanroom monitoring asks for. It buys a sensor that can be used as a reference for other sensors in the same installation, and it buys the documentation to prove it.</p>
<p>The interface flexibility matters in practice: I²C where the bus is shared, SPI where the sensor sits on a long cable or next to switching noise. Both are supported by the same part, so a board can change bus without changing the footprint.</p>
<h2>Key features</h2>
<ul>
<li>±1.5% RH and ±0.1 °C accuracy</li>
<li>Both I²C and SPI on the same package</li>
<li>0.4 µA average current at one measurement per minute</li>
<li>Low supply range for battery and 1.8 V logic systems</li>
<li>Calibrated digital output, no external components</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Cleanroom and regulated storage monitoring</li>
<li>Pharmaceutical stability chambers</li>
<li>Reference sensor in multi-point installations</li>
<li>Battery-powered data loggers</li>
</ul>
<h2>Selection note</h2>
<p>Calibration drift is dominated by contamination. Protect the opening with a filter and keep the sensor away from solvents, adhesives and silicone vapours during assembly.</p>
<h2>Ordering</h2>
<p>Send the accuracy class, interface, supply and calibration documentation required. We confirm the filter and packaging, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/high-accuracy-rh-t-sensor-15pct/">High-Accuracy Humidity &#038; Temperature Sensor, ±1.5% RH</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Modbus RTU Humidity &#038; Temperature Probe, IP65</title>
		<link>https://www.duomy.com/products/modbus-rh-t-probe-ip65/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:41 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/modbus-rh-t-probe-ip65/</guid>

					<description><![CDATA[<p>Industrial humidity and temperature probe with Modbus RTU output, IP65 stainless housing, 12 to 24 V supply. Direct connection to PLC and SCADA systems without an analogue front end.</p>
<p>The post <a href="https://www.duomy.com/products/modbus-rh-t-probe-ip65/">Modbus RTU Humidity &#038; Temperature Probe, IP65</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A probe with a Modbus output is a sensor and a transmitter in one housing: it measures, linearises, and answers a register read. The PLC sees a number over RS485 and the analogue input card, the signal conditioning and the calibration step all disappear from the design.</p>
<p>The sintered stainless filter is what makes it survive a real installation. It keeps dust and water spray off the sensing element while letting water vapour through, which is the whole requirement for measuring humidity in a room that is washed down.</p>
<h2>Key features</h2>
<ul>
<li>Modbus RTU over RS485, 9,600 to 115,200 bps</li>
<li>IP65 stainless probe body with sintered filter</li>
<li>12 to 24 V DC supply</li>
<li>2 m cable, other lengths available</li>
<li>Direct PLC and SCADA connection</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Duct and room monitoring in HVAC systems</li>
<li>Cold rooms and food processing areas</li>
<li>Greenhouse and storage environment control</li>
<li>Water treatment plant rooms</li>
</ul>
<h2>Selection note</h2>
<p>Set a unique Modbus address for each probe before installation. Two devices on the same address on a shared bus will make the whole segment fail intermittently.</p>
<h2>Ordering</h2>
<p>Send the range, accuracy, cable length and bus topology. We confirm the register map and address setting procedure, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/modbus-rh-t-probe-ip65/">Modbus RTU Humidity &#038; Temperature Probe, IP65</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Digital Humidity &#038; Temperature Sensor, I²C, ±2% RH</title>
		<link>https://www.duomy.com/products/digital-rh-t-sensor-i2c-2pct/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:40 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/digital-rh-t-sensor-i2c-2pct/</guid>

					<description><![CDATA[<p>Digital relative humidity and temperature sensor, ±2% RH and ±0.2 °C, I²C interface, 2.4 to 5.5 V supply, DFN-8. Calibrated output with no external components.</p>
<p>The post <a href="https://www.duomy.com/products/digital-rh-t-sensor-i2c-2pct/">Digital Humidity &#038; Temperature Sensor, I²C, ±2% RH</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A calibrated digital RH/T sensor removes the analogue front end from the design: no reference resistor, no op-amp, no calibration fixture. The part measures, linearises and compensates internally, and the microcontroller reads a 16-bit value over two wires.</p>
<p>The accuracy figure is only valid where the sensor sits. Mounted next to a regulator or a processor, it reports the board temperature, not the air temperature. A slot in the enclosure and a few millimetres of separation from heat sources are worth more than a tighter specification on the datasheet.</p>
<h2>Key features</h2>
<ul>
<li>±2% RH and ±0.2 °C calibrated accuracy</li>
<li>I²C interface, 16-bit output</li>
<li>1.2 µA average current at one measurement per second</li>
<li>2.4 to 5.5 V supply, no external components</li>
<li>DFN-8 package, 2.5 × 2.5 mm</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>HVAC duct and room sensors</li>
<li>Cold chain and food storage monitoring</li>
<li>Pharmaceutical storage environments</li>
<li>Indoor air quality equipment</li>
</ul>
<h2>Selection note</h2>
<p>Keep the sensor away from heat sources and out of direct airflow from a fan. Both give a reading that is stable and wrong.</p>
<h2>Ordering</h2>
<p>Send the accuracy target, interface, supply voltage and enclosure arrangement. We confirm the filter option and quote with the recommended footprint.</p>
<p>The post <a href="https://www.duomy.com/products/digital-rh-t-sensor-i2c-2pct/">Digital Humidity &#038; Temperature Sensor, I²C, ±2% RH</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>