<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fuses &amp; PTCs | Sensors &amp; Electronic Components - DuoMy</title>
	<atom:link href="https://www.duomy.com/product-category/fuses/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.duomy.com/product-category/fuses/</link>
	<description></description>
	<lastBuildDate>Fri, 20 Nov 2026 01:06:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://www.duomy.com/wp-content/uploads/2026/04/cropped-电子-32x32.png</url>
	<title>Fuses &amp; PTCs | Sensors &amp; Electronic Components - DuoMy</title>
	<link>https://www.duomy.com/product-category/fuses/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>5 × 20 mm Glass Cartridge Fuse, 6.3 A 250 V, Time-Lag</title>
		<link>https://www.duomy.com/products/5x20-glass-cartridge-fuse-63a/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:39 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/5x20-glass-cartridge-fuse-63a/</guid>

					<description><![CDATA[<p>5 × 20 mm glass cartridge fuse, 6.3 A, 250 V AC, time-lag characteristic, 150 A breaking capacity. Mains input protection in equipment with a replaceable fuse holder.</p>
<p>The post <a href="https://www.duomy.com/products/5x20-glass-cartridge-fuse-63a/">5 × 20 mm Glass Cartridge Fuse, 6.3 A 250 V, Time-Lag</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A glass cartridge fuse in a panel holder is the classic mains input protection: visible, replaceable without desoldering, and cheap enough that every piece of equipment can have one. The time-lag characteristic absorbs the inrush of a transformer or a switching supply without opening on every switch-on.</p>
<p>The glass body is also the diagnostic. A blown fuse can be seen through the tube, and whether the element is melted with a bead or sprayed on the glass tells a technician whether the fault was a slow overload or a hard short.</p>
<h2>Key features</h2>
<ul>
<li>Time-lag characteristic for transformer and SMPS inrush</li>
<li>250 V AC, 6.3 A, 150 A breaking capacity</li>
<li>Glass body for visual fault inspection</li>
<li>IEC 60127-2 sheet 3 dimensions</li>
<li>Nickel-plated brass end caps</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Mains input protection in panel-mounted equipment</li>
<li>Transformer primary protection</li>
<li>Switching supply input protection</li>
<li>Laboratory and test equipment</li>
</ul>
<h2>Selection note</h2>
<p>Never fit a higher-rated fuse to stop repeat failures. A fuse that opens repeatedly is reporting a fault, and the next component to fail will be more expensive.</p>
<h2>Ordering</h2>
<p>Send the input voltage, steady current and inrush profile, plus the holder type. We confirm the characteristic and breaking capacity, then quote per box.</p>
<p>The post <a href="https://www.duomy.com/products/5x20-glass-cartridge-fuse-63a/">5 × 20 mm Glass Cartridge Fuse, 6.3 A 250 V, Time-Lag</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PTC Resettable Fuse, 1.1 A 60 V, Radial</title>
		<link>https://www.duomy.com/products/ptc-resettable-fuse-11a-60v/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:39 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/ptc-resettable-fuse-11a-60v/</guid>

					<description><![CDATA[<p>Radial polymer PTC resettable fuse, 1.1 A hold current, 60 V, 2.2 A trip current. Self-resetting overcurrent protection for ports and low-voltage branches.</p>
<p>The post <a href="https://www.duomy.com/products/ptc-resettable-fuse-11a-60v/">PTC Resettable Fuse, 1.1 A 60 V, Radial</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A PTC does not blow; it heats, changes resistance by orders of magnitude, and holds the current to a trickle until the fault is removed. That behaviour suits ports and branches where a technician cannot reach a fuse, and where an intermittent fault should not require a service call.</p>
<p>The catch is that a PTC is a thermal device. Hold current falls as ambient rises, so a part rated 1.1 A at 25 °C may only hold 0.7 A at 70 °C. Derate for the real enclosure temperature, and remember that the device stays warm and resistive for a while after the fault clears.</p>
<h2>Key features</h2>
<ul>
<li>Self-resetting, no replacement needed</li>
<li>1.1 A hold, 2.2 A trip current at 25 °C</li>
<li>60 V maximum, 40 A fault current capability</li>
<li>Radial package with 5.1 mm lead spacing</li>
<li>Automatic recovery once the fault is removed</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Port and interface overcurrent protection</li>
<li>Low-voltage branch protection in enclosures</li>
<li>Motor stall protection on small actuators</li>
<li>Equipment in inaccessible locations</li>
</ul>
<h2>Selection note</h2>
<p>Derate the hold current for ambient temperature. At 70 °C, expect roughly 60% of the 25 °C rating, and check the derating curve before choosing the part.</p>
<h2>Ordering</h2>
<p>Send the normal current, trip current required, maximum voltage and ambient temperature. We apply the derating curve and quote the resulting part.</p>
<p>The post <a href="https://www.duomy.com/products/ptc-resettable-fuse-11a-60v/">PTC Resettable Fuse, 1.1 A 60 V, Radial</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>0603 Fast-Acting SMD Fuse, 500 mA 32 V</title>
		<link>https://www.duomy.com/products/0603-fast-acting-smd-fuse-500ma/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/0603-fast-acting-smd-fuse-500ma/</guid>

					<description><![CDATA[<p>Fast-acting surface-mount fuse in an 0603 body, 500 mA, 32 V DC, 50 A breaking capacity. Tight overcurrent protection for small boards and delicate circuits.</p>
<p>The post <a href="https://www.duomy.com/products/0603-fast-acting-smd-fuse-500ma/">0603 Fast-Acting SMD Fuse, 500 mA 32 V</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>Fast-acting fuses are specified where the protected device is more fragile than the wiring: a sensor front end, a communication transceiver, or a small regulator that would be destroyed by a sustained fault long before a slow-blow part reacted. Half an amp in an 0603 is the smallest practical size for that job.</p>
<p>The trade is susceptibility to inrush. Any capacitance on the protected rail charges through the fuse on every power-up, and a fast characteristic with a low melting I²t may not survive it. If nuisance openings appear, the answer is usually a soft-start or a larger fuse, not a slower one.</p>
<h2>Key features</h2>
<ul>
<li>Fast-acting characteristic for delicate circuits</li>
<li>500 mA rating in an 0603 body</li>
<li>50 A breaking capacity at 32 V DC</li>
<li>Low melting I²t for rapid fault clearing</li>
<li>Reflow-compatible construction</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Sensor and transceiver supply protection</li>
<li>Small regulator input protection</li>
<li>USB and interface port protection</li>
<li>Battery-powered instruments</li>
</ul>
<h2>Selection note</h2>
<p>Unmarked 0603 fuses are indistinguishable by eye once assembled. Maintain a labelled bin and a first-article check, or use a marked body for anything that will be serviced.</p>
<h2>Ordering</h2>
<p>Send the steady-state current, inrush waveform and fault current available. We confirm the characteristic and breaking capacity, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/0603-fast-acting-smd-fuse-500ma/">0603 Fast-Acting SMD Fuse, 500 mA 32 V</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>1206 Slow-Blow SMD Fuse, 2 A 32 V</title>
		<link>https://www.duomy.com/products/1206-slow-blow-smd-fuse-2a/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/1206-slow-blow-smd-fuse-2a/</guid>

					<description><![CDATA[<p>Slow-blow surface-mount fuse in a 1206 body, 2 A, 32 V DC, 50 A breaking capacity. Board-level overcurrent protection that tolerates inrush without nuisance trips.</p>
<p>The post <a href="https://www.duomy.com/products/1206-slow-blow-smd-fuse-2a/">1206 Slow-Blow SMD Fuse, 2 A 32 V</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A fuse is the one component whose job is to fail, and the design question is only whether it fails at the right current. A slow-blow characteristic is what allows a circuit with a capacitive load or a small motor to start without opening the fuse, while still clearing a genuine short.</p>
<p>The breaking capacity matters as much as the current rating. Fifty amps at 32 V DC is enough for a board fed from a battery or a local supply; a fuse with a lower breaking capacity can arc internally on a hard short and keep conducting through a carbon path instead of clearing.</p>
<h2>Key features</h2>
<ul>
<li>Slow-blow characteristic for inrush-tolerant protection</li>
<li>2 A rating, 32 V DC, 50 A breaking capacity</li>
<li>1206 body compatible with standard SMT placement</li>
<li>Defined melting I²t for coordination with the supply</li>
<li>Marked with rated current for inspection</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Board-level overcurrent protection</li>
<li>Battery-powered equipment input protection</li>
<li>Motor and solenoid branch protection</li>
<li>Secondary protection after a resettable device</li>
</ul>
<h2>Selection note</h2>
<p>Verify the melting I²t against the inrush energy of the load. A fuse that opens on every power-up is not protecting anything, it is just failing slowly.</p>
<h2>Ordering</h2>
<p>Send the normal current, inrush profile, supply voltage and required breaking capacity. We confirm the characteristic curve and quote per reel.</p>
<p>The post <a href="https://www.duomy.com/products/1206-slow-blow-smd-fuse-2a/">1206 Slow-Blow SMD Fuse, 2 A 32 V</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		