	<title>Power Modules | Sensors &amp; Electronic Components - DuoMy</title>
	<atom:link href="https://www.duomy.com/product-category/power-modules/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.duomy.com/product-category/power-modules/</link>
	<description></description>
	<lastBuildDate>Fri, 20 Nov 2026 01:18:00 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://www.duomy.com/wp-content/uploads/2026/04/cropped-电子-32x32.png</url>
	<title>Power Modules | Sensors &amp; Electronic Components - DuoMy</title>
	<link>https://www.duomy.com/product-category/power-modules/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>20 W Wide-Input Isolated DC-DC, 9–36 V to 12 V</title>
		<link>https://www.duomy.com/products/20w-wide-input-isolated-dc-dc-9-36v-12v/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:18:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/20w-wide-input-isolated-dc-dc-9-36v-12v/</guid>

					<description><![CDATA[<p>Isolated DC-DC converter module, 9 to 36 V input, 12 V 1.67 A output, 1.5 kV isolation, DIP-6 package. Wide input range covers 12 V and 24 V systems with one part.</p>
<p>The post <a href="https://www.duomy.com/products/20w-wide-input-isolated-dc-dc-9-36v-12v/">20 W Wide-Input Isolated DC-DC, 9–36 V to 12 V</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A 9 to 36 V input window covers a 12 V battery with sag, a 24 V industrial rail with surge, and everything between, so one part number serves several product variants. That is the practical reason wide-input modules exist: fewer line items, fewer spares, one qualification.</p>
<p>At 88% efficiency and 20 W, the module dissipates about 2.7 W, which the DIP package sheds through its pins and the surrounding copper. It is a component to be placed with airflow in mind rather than tucked into a corner.</p>
<h2>Key features</h2>
<ul>
<li>9 to 36 V input covers 12 V and 24 V systems</li>
<li>12 V 1.67 A isolated output</li>
<li>88% efficiency at full load</li>
<li>DIP-6 package with through-hole pins</li>
<li>Short-circuit and over-voltage protected</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>24 V industrial rail to 12 V isolated rail</li>
<li>Vehicle and battery-powered equipment</li>
<li>Communication gateway supplies</li>
<li>Instrumentation with floating outputs</li>
</ul>
<h2>Selection note</h2>
<p>Add input and output capacitors as shown in the data sheet, even though the module works without them. They are what keeps the ripple inside the specification over temperature.</p>
<h2>Ordering</h2>
<p>Send the input range, output voltage and current, and the ambient. We confirm derating and the filter components, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/20w-wide-input-isolated-dc-dc-9-36v-12v/">20 W Wide-Input Isolated DC-DC, 9–36 V to 12 V</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>600 V 10 A Intelligent Power Module, Three-Phase</title>
		<link>https://www.duomy.com/products/600v-10a-ipm-three-phase/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:18:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/600v-10a-ipm-three-phase/</guid>

					<description><![CDATA[<p>Intelligent power module, 600 V 10 A, three-phase inverter with gate drivers, bootstrap supply and protection integrated. Six switches, one part number, protected output stage.</p>
<p>The post <a href="https://www.duomy.com/products/600v-10a-ipm-three-phase/">600 V 10 A Intelligent Power Module, Three-Phase</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>An intelligent power module is a three-phase inverter with its gate drivers, bootstrap diodes and protection comparators already inside. The microcontroller sees six logic inputs, a fault output and three phase terminals, and the design work that remains is the current sensing and the thermal path.</p>
<p>The protection is the part that justifies the cost. Short-circuit detection inside the module reacts in microseconds, faster than firmware polling a shunt could, and it turns the switch off before the device is destroyed. That is a safety function that is hard to build well from discrete parts.</p>
<h2>Key features</h2>
<ul>
<li>Six IGBTs with integrated gate drivers</li>
<li>Bootstrap supply for the high-side drive</li>
<li>Short-circuit and under-voltage protection</li>
<li>Fault output for controller monitoring</li>
<li>1 to 20 kHz switching range</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Appliance compressor and fan drives</li>
<li>Small pump and blower inverters</li>
<li>HVAC variable-speed drives</li>
<li>Compact three-phase motor control</li>
</ul>
<h2>Selection note</h2>
<p>The bootstrap capacitors set the high-side drive margin at low switching frequency. Below about 2 kHz, check that the bootstrap supply is refreshed often enough for the gate charge required.</p>
<h2>Ordering</h2>
<p>Send the motor rating, bus voltage, switching frequency and control interface. We confirm the module current class and protection thresholds, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/600v-10a-ipm-three-phase/">600 V 10 A Intelligent Power Module, Three-Phase</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>5 W Isolated DC-DC Converter, 24 V to 5 V, SIP-4</title>
		<link>https://www.duomy.com/products/5w-isolated-dc-dc-24v-5v-sip/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:17:59 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/5w-isolated-dc-dc-24v-5v-sip/</guid>

					<description><![CDATA[<p>Isolated DC-DC converter module, 18 to 36 V input, 5 V 1 A output, 1.5 kV isolation, SIP-4 package. A complete isolated rail without a transformer design.</p>
<p>The post <a href="https://www.duomy.com/products/5w-isolated-dc-dc-24v-5v-sip/">5 W Isolated DC-DC Converter, 24 V to 5 V, SIP-4</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>An isolated DC-DC module is a transformer, a controller and a feedback loop in a 20 mm package. It exists because designing an isolated 5 W supply from discrete parts is a week of work and a stack of magnetics samples, while the module is a single line on the bill of materials.</p>
<p>The isolation is what it is bought for: breaking a ground loop between a sensor front end and a controller, or powering a communication interface that must float relative to the main circuit. At 1.5 kV it covers functional isolation, not the reinforced isolation a mains-facing circuit requires.</p>
<h2>Key features</h2>
<ul>
<li>18 to 36 V input, 5 V 1 A output</li>
<li>1.5 kV DC isolation between input and output</li>
<li>SIP-4 package, no external components</li>
<li>78% efficiency at full load</li>
<li>Short-circuit protected output</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Isolated sensor and interface supplies</li>
<li>Breaking ground loops in measurement systems</li>
<li>RS-485 and CAN bus isolation</li>
<li>Auxiliary rails in industrial controls</li>
</ul>
<h2>Selection note</h2>
<p>A 5 W module in a sealed enclosure needs derating above 70 °C. Check the derating curve and, if the load is continuous at full current, mount the module where air can reach it.</p>
<h2>Ordering</h2>
<p>Send the input range, output voltage and current, and the isolation class required. We confirm the module against the load profile, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/5w-isolated-dc-dc-24v-5v-sip/">5 W Isolated DC-DC Converter, 24 V to 5 V, SIP-4</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>600 V 15 A IGBT Half-Bridge Module</title>
		<link>https://www.duomy.com/products/600v-15a-igbt-half-bridge-module/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:17:58 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/600v-15a-igbt-half-bridge-module/</guid>

					<description><![CDATA[<p>IGBT half-bridge module, 600 V 15 A per switch, with matched freewheeling diodes and isolated baseplate. One part carries the whole commutation loop for a half-bridge stage.</p>
<p>The post <a href="https://www.duomy.com/products/600v-15a-igbt-half-bridge-module/">600 V 15 A IGBT Half-Bridge Module</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A half-bridge module puts both switches and their diodes inside one package, so the commutation loop is defined by the manufacturer instead of by your layout. That is the whole value: the loop inductance that causes turn-off overshoot is fixed and characterised, rather than depending on how the board was routed.</p>
<p>It also removes the isolated mounting problem. The baseplate is isolated from the terminals, so the module bolts to an earthed heatsink and the gate driver only has to bridge the gate-to-emitter isolation, not the full bus voltage.</p>
<h2>Key features</h2>
<ul>
<li>Two IGBTs and two diodes in one package</li>
<li>Characterised commutation loop</li>
<li>Isolated baseplate, 2,500 V AC</li>
<li>Solder-pin power and gate terminals</li>
<li>1.6 °C/W junction-to-case</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Half-bridge and full-bridge inverters</li>
<li>Motor drive output stages</li>
<li>Induction heating generators</li>
<li>Welding and plasma supplies</li>
</ul>
<h2>Selection note</h2>
<p>Follow the gate driver layout in the module data sheet. The internal loop is characterised, but the gate loop is still yours, and a long gate return reintroduces the ringing the module was meant to remove.</p>
<h2>Ordering</h2>
<p>Send the bus voltage, switching frequency, current and topology. We confirm the module class and gate driver requirement, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/600v-15a-igbt-half-bridge-module/">600 V 15 A IGBT Half-Bridge Module</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>