<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Common-Mode Chokes &amp; Ferrite Beads | Sensors &amp; Electronic Components - DuoMy</title>
	<atom:link href="https://www.duomy.com/product-category/common-mode-chokes-ferrite-beads/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.duomy.com/product-category/common-mode-chokes-ferrite-beads/</link>
	<description></description>
	<lastBuildDate>Fri, 20 Nov 2026 01:17:23 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://www.duomy.com/wp-content/uploads/2026/04/cropped-电子-32x32.png</url>
	<title>Common-Mode Chokes &amp; Ferrite Beads | Sensors &amp; Electronic Components - DuoMy</title>
	<link>https://www.duomy.com/product-category/common-mode-chokes-ferrite-beads/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Signal Common-Mode Choke, 2 × 51 µH, 100 mA, SMD</title>
		<link>https://www.duomy.com/products/signal-common-mode-choke-2x51uh/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:17:23 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/signal-common-mode-choke-2x51uh/</guid>

					<description><![CDATA[<p>Surface-mount common-mode choke, 2 × 51 µH, 100 mA, four-terminal package. For CAN, RS-485 and USB differential pairs that need common-mode impedance without loading the signal.</p>
<p>The post <a href="https://www.duomy.com/products/signal-common-mode-choke-2x51uh/">Signal Common-Mode Choke, 2 × 51 µH, 100 mA, SMD</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>On a differential bus, the signal is the voltage between two conductors and the noise is usually the voltage on both of them together. A common-mode choke passes the differential signal because the currents cancel in the core, and blocks the common-mode component because both currents flow the same way.</p>
<p>Fifty-one microhenry is the value that keeps the eye diagram intact at CAN and RS-485 data rates while still attenuating the common-mode component that radiates from the cable. At 100 mA it suits a signal line, not a power pair.</p>
<h2>Key features</h2>
<ul>
<li>2 × 51 µH for differential bus lines</li>
<li>600 Ω common-mode impedance at 10 MHz</li>
<li>Four-terminal SMD package, 3.2 × 2.5 mm</li>
<li>Differential signal passes with minimal distortion</li>
<li>100 mA rated current per winding</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>CAN and CAN FD bus filtering</li>
<li>RS-485 and RS-422 lines</li>
<li>USB and Ethernet magnetics</li>
<li>Sensor bus entries on industrial equipment</li>
</ul>
<h2>Selection note</h2>
<p>Route the pair as a tightly coupled differential trace through the choke and keep the two windings on the correct sides. Reversing one winding turns the choke into a series inductor for the signal.</p>
<h2>Ordering</h2>
<p>Send the bus type, data rate and common-mode noise level. We confirm the inductance and cut-off, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/signal-common-mode-choke-2x51uh/">Signal Common-Mode Choke, 2 × 51 µH, 100 mA, SMD</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Common-Mode Choke, 2 × 10 mH, 1.5 A, Through-Hole</title>
		<link>https://www.duomy.com/products/common-mode-choke-2x10mh-1r5a/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:17:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/common-mode-choke-2x10mh-1r5a/</guid>

					<description><![CDATA[<p>Through-hole common-mode choke, 2 × 10 mH, 1.5 A per winding, 250 V AC. Differential current cancels in the core while common-mode noise sees the full inductance.</p>
<p>The post <a href="https://www.duomy.com/products/common-mode-choke-2x10mh-1r5a/">Common-Mode Choke, 2 × 10 mH, 1.5 A, Through-Hole</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A common-mode choke is two windings on one core, wired so that the supply current flows in opposite directions. The magnetic flux from the differential current cancels, so the core does not saturate at the operating current, while common-mode noise flowing the same way in both windings sees the full inductance.</p>
<p>That asymmetry is the whole point. A single inductor of 10 mH carrying 1.5 A would be large and would saturate; the choke delivers the same common-mode impedance in a 18 mm toroid because the working flux cancels. It is the second stage of almost every mains filter.</p>
<h2>Key features</h2>
<ul>
<li>2 × 10 mH on a single toroidal core</li>
<li>1.5 A per winding without saturation</li>
<li>1,500 V AC winding-to-winding insulation</li>
<li>2 kΩ impedance at 1 MHz</li>
<li>Four-pin through-hole mounting</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Mains input EMI filters</li>
<li>Common-mode noise suppression on supply lines</li>
<li>Motor drive input filtering</li>
<li>Industrial power entry modules</li>
</ul>
<h2>Selection note</h2>
<p>Keep the two windings separated on the layout and avoid routing a trace between them. Capacitive coupling across the choke bypasses the inductance and defeats the filter at high frequency.</p>
<h2>Ordering</h2>
<p>Send the line current, mains voltage and target attenuation. We confirm the inductance and insulation class, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/common-mode-choke-2x10mh-1r5a/">Common-Mode Choke, 2 × 10 mH, 1.5 A, Through-Hole</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>0805 Ferrite Bead, 1 kΩ at 100 MHz, 300 mA</title>
		<link>https://www.duomy.com/products/0805-ferrite-bead-1k-300ma/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:17:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/0805-ferrite-bead-1k-300ma/</guid>

					<description><![CDATA[<p>Surface-mount ferrite bead in 0805, 1 kΩ impedance at 100 MHz, 300 mA rated current. Higher impedance in a larger body for signal lines and low-current supply filtering.</p>
<p>The post <a href="https://www.duomy.com/products/0805-ferrite-bead-1k-300ma/">0805 Ferrite Bead, 1 kΩ at 100 MHz, 300 mA</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A thousand ohms at 100 MHz is enough to break a radiated path on a signal line: the bead adds series impedance at the frequency where the trace would otherwise act as an antenna, without loading the line at the signal frequency. That is why it appears at connector entries and on the analogue side of an ADC.</p>
<p>The trade is current. At 300 mA and 0.5 Ω the part is intended for signal and low-current supply lines, not for a motor or a heater. On a line that carries real current, a larger bead with a higher saturation current is required.</p>
<h2>Key features</h2>
<ul>
<li>1 kΩ at 100 MHz for signal-line damping</li>
<li>300 mA rated current, 0.5 Ω DCR</li>
<li>0805 body with a wide impedance band</li>
<li>Multilayer construction, no winding resonance</li>
<li>Suitable for connector entry filtering</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>ADC and sensor signal line filtering</li>
<li>Connector entry suppression</li>
<li>Low-current supply isolation</li>
<li>Audio and reference line damping</li>
</ul>
<h2>Selection note</h2>
<p>On a high-impedance signal line, a 1 kΩ bead at 100 MHz can interact with trace capacitance and shift the response. Check the S-parameters if the line carries a wideband signal.</p>
<h2>Ordering</h2>
<p>Send the line current, noise frequency and signal bandwidth. We confirm the impedance and the effect on the signal path, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/0805-ferrite-bead-1k-300ma/">0805 Ferrite Bead, 1 kΩ at 100 MHz, 300 mA</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>0603 Ferrite Bead, 600 Ω at 100 MHz, 500 mA</title>
		<link>https://www.duomy.com/products/0603-ferrite-bead-600r-500ma/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:17:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/0603-ferrite-bead-600r-500ma/</guid>

					<description><![CDATA[<p>Surface-mount ferrite bead in 0603, 600 Ω impedance at 100 MHz, 500 mA rated current, 0.35 Ω DC resistance. Damping for high-frequency noise on supply and signal lines.</p>
<p>The post <a href="https://www.duomy.com/products/0603-ferrite-bead-600r-500ma/">0603 Ferrite Bead, 600 Ω at 100 MHz, 500 mA</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A ferrite bead is a frequency-dependent resistor: near zero impedance at DC, several hundred ohms at 100 MHz. That shape is what makes it useful on a supply pin, where it passes the DC current the circuit needs while damping the high-frequency current that would otherwise radiate off the board.</p>
<p>The rated current is a thermal limit, not a signal limit. At 500 mA the 0.35 Ω resistance dissipates 87 mW, which the 0603 body can shed. Push 1 A through the same part and the impedance collapses as the ferrite saturates, so the bead stops filtering at exactly the current where the noise is worst.</p>
<h2>Key features</h2>
<ul>
<li>600 Ω at 100 MHz, 900 Ω at 1 GHz</li>
<li>500 mA rated current, 0.35 Ω DCR</li>
<li>0603 body for placement next to the pin</li>
<li>Multilayer construction, no winding resonance</li>
<li>Reflow-compatible terminations</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Supply pin filtering on ICs and modules</li>
<li>Damping of clock and data line ringing</li>
<li>Isolation between analogue and digital supplies</li>
<li>Cable and connector entry filtering</li>
</ul>
<h2>Selection note</h2>
<p>Check the impedance at the frequency that actually causes the problem. A bead chosen for 100 MHz does little for a 10 MHz resonance, and the impedance curve is not flat.</p>
<h2>Ordering</h2>
<p>Send the noise frequency, line current and available footprint. We confirm the impedance curve at that frequency, then quote per reel.</p>
<p>The post <a href="https://www.duomy.com/products/0603-ferrite-bead-600r-500ma/">0603 Ferrite Bead, 600 Ω at 100 MHz, 500 mA</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		