<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sensors &amp; Modules | Sensors &amp; Electronic Components - DuoMy</title>
	<atom:link href="https://www.duomy.com/product-category/sensors-modules/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.duomy.com/product-category/sensors-modules/</link>
	<description></description>
	<lastBuildDate>Fri, 20 Nov 2026 01:29:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://www.duomy.com/wp-content/uploads/2026/04/cropped-电子-32x32.png</url>
	<title>Sensors &amp; Modules | Sensors &amp; Electronic Components - DuoMy</title>
	<link>https://www.duomy.com/product-category/sensors-modules/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Diffuse Photoelectric Sensor, 300 mm, NPN, IP67</title>
		<link>https://www.duomy.com/products/photoelectric-sensor-diffuse-30cm-ip67/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:10 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/photoelectric-sensor-diffuse-30cm-ip67/</guid>

					<description><![CDATA[<p>Diffuse-reflective photoelectric sensor, 300 mm sensing range, NPN open collector output, 12 to 24 V supply, IP67. Detects presence without a separate reflector or receiver.</p>
<p>The post <a href="https://www.duomy.com/products/photoelectric-sensor-diffuse-30cm-ip67/">Diffuse Photoelectric Sensor, 300 mm, NPN, IP67</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A diffuse sensor emits light and detects what bounces back from the target itself, so it needs no reflector and no second unit. That halves the wiring and removes the alignment step, which is why it is the default choice for part-present detection on a conveyor.</p>
<p>The limitation is that the sensing range depends on the target. A white carton reflects well at 300 mm; a black rubber part may only be detected at 80 mm. The range printed on the datasheet assumes a 90 percent reflectance target, so the adjustment has to be made against the real product.</p>
<h2>Key features</h2>
<ul>
<li>No reflector required, single-sided installation</li>
<li>10 to 300 mm adjustable range</li>
<li>NPN open collector output, light-on or dark-on</li>
<li>1 ms response for fast moving parts</li>
<li>IP67 M18 housing with a 2 m cable</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Part-present detection on conveyors</li>
<li>Bottle and carton counting</li>
<li>Gate and flap position sensing</li>
<li>Presence checks in packaging machines</li>
</ul>
<h2>Selection note</h2>
<p>Test the range against the actual product, not a white card. Dark, matte or transparent targets reduce the usable distance sharply, and a transparent bottle may need a reflective or through-beam type instead.</p>
<h2>Ordering</h2>
<p>Send the target material, colour, size and required distance, plus the PLC input type. We confirm diffuse against through-beam, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/photoelectric-sensor-diffuse-30cm-ip67/">Diffuse Photoelectric Sensor, 300 mm, NPN, IP67</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Slot Photointerrupter, 5 mm Gap, Phototransistor, PCB Mount</title>
		<link>https://www.duomy.com/products/slot-sensor-photointerrupter-5mm/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:10 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/slot-sensor-photointerrupter-5mm/</guid>

					<description><![CDATA[<p>Photointerrupter with a 5 mm slot, 950 nm infrared emitter and phototransistor output, PCB mount. Detects a flag, vane or disc edge with no alignment and no ambient light sensitivity.</p>
<p>The post <a href="https://www.duomy.com/products/slot-sensor-photointerrupter-5mm/">Slot Photointerrupter, 5 mm Gap, Phototransistor, PCB Mount</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A photointerrupter puts the emitter and detector in one moulding facing each other across a fixed gap. The optical path is enclosed, so ambient light, dust on a lens and alignment error all stop being variables. The only thing that breaks the beam is the flag the designer puts there.</p>
<p>That makes it the standard part for end-of-travel and index detection on small mechanisms: printer carriage home, valve position, encoder disc edge, shutter status. The 15 µs response is fast enough for a disc with hundreds of slots at a few thousand rpm.</p>
<h2>Key features</h2>
<ul>
<li>Fixed 5 mm optical gap, no alignment procedure</li>
<li>Enclosed optical path, insensitive to ambient light</li>
<li>15 µs response time</li>
<li>Through-hole PCB mounting on a 2.54 mm pitch</li>
<li>Infrared emitter, works with opaque flags of any colour</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>End-of-travel and home position detection</li>
<li>Encoder disc and index sensing</li>
<li>Valve and shutter position feedback</li>
<li>Paper and label edge detection</li>
</ul>
<h2>Selection note</h2>
<p>Size the flag to block the full 5 mm slot with a few tenths of a millimetre of overlap. A flag that only partly enters the beam still produces a valid output at rest and fails when the mechanism wears.</p>
<h2>Ordering</h2>
<p>Send the slot width, flag thickness, mechanism speed and output interface. We confirm the housing and lead length, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/slot-sensor-photointerrupter-5mm/">Slot Photointerrupter, 5 mm Gap, Phototransistor, PCB Mount</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>High-Speed Optocoupler, 10 Mbit/s, Logic Output, SOIC-8</title>
		<link>https://www.duomy.com/products/optocoupler-high-speed-10mbit-soic8/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/optocoupler-high-speed-10mbit-soic8/</guid>

					<description><![CDATA[<p>Logic-output optocoupler, 10 Mbit/s, 3.75 kVrms isolation, 25 ns propagation delay. For isolating SPI, UART and encoder signals where a phototransistor is too slow and too gain-dependent.</p>
<p>The post <a href="https://www.duomy.com/products/optocoupler-high-speed-10mbit-soic8/">High-Speed Optocoupler, 10 Mbit/s, Logic Output, SOIC-8</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A phototransistor optocoupler is limited by the base-collector capacitance of the detector, which sets a rise time in the microseconds. A high-speed part puts a photodiode and a CMOS comparator on the output side instead, so the delay drops to tens of nanoseconds and the output is a clean logic level rather than a current.</p>
<p>That removes the CTR problem entirely: the output is digital, so there is no gain to fall out of bed with temperature. The price is that the part needs a supply on both sides, which a phototransistor does not, and the isolation rating is typically lower because the die is smaller.</p>
<h2>Key features</h2>
<ul>
<li>10 Mbit/s with 25 ns propagation delay</li>
<li>CMOS output, no CTR or gain calculation needed</li>
<li>15 kV/µs common-mode transient immunity</li>
<li>3.75 kVrms isolation in an SOIC-8 package</li>
<li>3.0 to 5.5 V supply on both sides</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Isolated SPI and UART links</li>
<li>Encoder and resolver interfaces</li>
<li>Fieldbus and CAN isolation</li>
<li>Isolated gate driver signal paths</li>
</ul>
<h2>Selection note</h2>
<p>Keep the isolation barrier clear of copper on both sides. A ground pour that crosses under the package defeats the creepage and creates a path for exactly the transient the part is meant to block.</p>
<h2>Ordering</h2>
<p>Send the data rate, supply voltages, isolation class and delay budget. We confirm the output type and package, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/optocoupler-high-speed-10mbit-soic8/">High-Speed Optocoupler, 10 Mbit/s, Logic Output, SOIC-8</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Phototransistor Optocoupler, 5 kVrms, CTR 50–600%, SOP-4</title>
		<link>https://www.duomy.com/products/optocoupler-phototransistor-5kv-sop4/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:08 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/optocoupler-phototransistor-5kv-sop4/</guid>

					<description><![CDATA[<p>Phototransistor optocoupler in SOP-4, 5 kVrms isolation, current transfer ratio 50 to 600 percent. For galvanic isolation of digital signals, feedback loops and gate drive interfaces.</p>
<p>The post <a href="https://www.duomy.com/products/optocoupler-phototransistor-5kv-sop4/">Phototransistor Optocoupler, 5 kVrms, CTR 50–600%, SOP-4</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>An optocoupler breaks the galvanic path with light. There is no shared conductor, no common ground and no path for a fault current to travel from a 400 V bus into a microcontroller, which is the reason the part survives in designs where digital isolators are cheaper and faster.</p>
<p>The CTR is the number that catches people out. It is not a fixed gain: it falls with temperature, falls with age and varies by a factor of ten between parts. A design that works with a nominal CTR of 300 will fail on a unit at the bottom of the 50 percent bin unless the base current is calculated for the worst case.</p>
<h2>Key features</h2>
<ul>
<li>5 kVrms isolation with 8 mm creepage</li>
<li>CTR 50 to 600 percent, binned on request</li>
<li>3 µs rise time, adequate for signals up to about 100 kHz</li>
<li>SOP-4 package, half the footprint of a DIP-4</li>
<li>35 V collector-emitter rating for direct logic interface</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Digital signal isolation</li>
<li>Feedback loops in isolated supplies</li>
<li>Gate drive interfaces for IGBTs and MOSFETs</li>
<li>Sensor interfaces crossing a safety barrier</li>
</ul>
<h2>Selection note</h2>
<p>Design the collector resistor for the minimum CTR at maximum temperature, not the typical value. A circuit sized at CTR 300 will not saturate on a unit at CTR 50 after ten years of degradation.</p>
<h2>Ordering</h2>
<p>Send the signal rate, isolation voltage, logic levels on both sides and ambient temperature. We confirm CTR bin and package, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/optocoupler-phototransistor-5kv-sop4/">Phototransistor Optocoupler, 5 kVrms, CTR 50–600%, SOP-4</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DC Voltage Transducer, 0–600 V to 4–20 mA, DIN Rail</title>
		<link>https://www.duomy.com/products/dc-voltage-transducer-600v-din/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:07 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/dc-voltage-transducer-600v-din/</guid>

					<description><![CDATA[<p>DIN-rail DC voltage transducer, 0 to 600 V input, 4 to 20 mA output, 0.5% of full scale, 2.5 kV isolation. Converts a high-voltage bus into a loop signal a PLC can read without an isolation amplifier on the card.</p>
<p>The post <a href="https://www.duomy.com/products/dc-voltage-transducer-600v-din/">DC Voltage Transducer, 0–600 V to 4–20 mA, DIN Rail</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A 600 V DC bus cannot be wired into an analogue input card. The card measures 0 to 10 V or 4 to 20 mA and has no isolation to speak of, so the transducer does two jobs at once: it scales the voltage down and it puts 2.5 kV of galvanic isolation between the bus and the control system.</p>
<p>The 4 to 20 mA loop is chosen over a voltage output because current does not drop across cable resistance. A 0 to 10 V signal over 200 m of cable loses a measurable fraction in the loop resistance; 4 to 20 mA reads the same at both ends, and a broken wire shows up as 0 mA rather than as a valid zero reading.</p>
<h2>Key features</h2>
<ul>
<li>0 to 600 V DC input, 4 to 20 mA two-wire output</li>
<li>2.5 kV isolation between input and output</li>
<li>0.5% of full scale accuracy</li>
<li>35 mm DIN rail mounting with screw terminals</li>
<li>Loop-powered, no separate auxiliary supply on the output side</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>DC bus and battery bank monitoring</li>
<li>Solar string and inverter voltage feedback</li>
<li>Telecom and UPS plant monitoring</li>
<li>PLC analogue input conditioning</li>
</ul>
<h2>Selection note</h2>
<p>Check the loop supply against the total burden. A 500 Ω load plus cable resistance at 20 mA needs at least 20 V at the transmitter terminals, which is close to the limit of a 24 V supply with a long cable run.</p>
<h2>Ordering</h2>
<p>Send the input range, output signal, loop supply and isolation requirement. We confirm the scaling and burden, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/dc-voltage-transducer-600v-din/">DC Voltage Transducer, 0–600 V to 4–20 mA, DIN Rail</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AC Current Transducer, 0–50 A True RMS to 4–20 mA, DIN Rail</title>
		<link>https://www.duomy.com/products/ac-current-transducer-50a-4-20ma/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:07 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/ac-current-transducer-50a-4-20ma/</guid>

					<description><![CDATA[<p>DIN-rail AC current transducer, 0 to 50 A true RMS input, 4 to 20 mA output, 1% accuracy. Reads distorted waveforms correctly where an averaging meter under-reports by 20 percent or more.</p>
<p>The post <a href="https://www.duomy.com/products/ac-current-transducer-50a-4-20ma/">AC Current Transducer, 0–50 A True RMS to 4–20 mA, DIN Rail</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>True RMS matters when the load is not a clean sine wave. A variable-frequency drive, a switched-mode supply or a phase-angle controller draws a current with a high crest factor, and an averaging meter calibrated for sine waves reads low by 10 to 30 percent. The protection threshold then trips late or never.</p>
<p>The trade-off is response time. True RMS conversion needs a measurement window, typically a few hundred milliseconds, so the output lags the actual current. For overload protection that is acceptable; for cycle-by-cycle current limiting it is not, and a shunt or Hall sensor is the correct choice.</p>
<h2>Key features</h2>
<ul>
<li>True RMS measurement, accurate on distorted waveforms</li>
<li>0 to 50 A input, 4 to 20 mA output</li>
<li>2.5 kV isolation between the primary and the loop</li>
<li>120% continuous overload without saturation</li>
<li>DIN rail mounting with screw terminals</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Motor and pump load monitoring</li>
<li>VFD-driven equipment current feedback</li>
<li>Heater and compressor run detection</li>
<li>Energy submetering on distorted loads</li>
</ul>
<h2>Selection note</h2>
<p>Do not use a true RMS transducer for fast protection. The 300 ms response is fine for trend and alarm thresholds but far too slow for short-circuit or phase-loss detection, which needs a dedicated protection relay.</p>
<h2>Ordering</h2>
<p>Send the current range, waveform type, response time and output signal. We confirm RMS versus instantaneous sensing, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/ac-current-transducer-50a-4-20ma/">AC Current Transducer, 0–50 A True RMS to 4–20 mA, DIN Rail</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Precision Current Shunt, 1 mΩ, ±0.5%, 10 W, 4-Terminal</title>
		<link>https://www.duomy.com/products/precision-shunt-1mohm-10w/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:06 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/precision-shunt-1mohm-10w/</guid>

					<description><![CDATA[<p>Four-terminal current shunt, 1 mΩ ±0.5%, 10 W continuous, 50 ppm/°C. Produces 100 mV at 100 A with Kelvin connections so the measurement does not include the solder joints.</p>
<p>The post <a href="https://www.duomy.com/products/precision-shunt-1mohm-10w/">Precision Current Shunt, 1 mΩ, ±0.5%, 10 W, 4-Terminal</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A shunt measures current by measuring voltage across a known resistance, so the accuracy of the measurement depends entirely on where the sense connections are made. Two-terminal shunts include the solder joint resistance in the reading; four-terminal parts bring out separate sense pins inside the element so the joint is excluded.</p>
<p>At 1 mΩ and 100 A the dissipation is 10 W, which is why the element is a solid metal bar rather than a film resistor. The temperature coefficient then becomes the dominant error: a 50 ppm/°C part that heats by 60 °C shifts by 3,000 ppm, or 0.3 percent, which is already most of the tolerance budget.</p>
<h2>Key features</h2>
<ul>
<li>Four-terminal Kelvin connection excludes joint resistance</li>
<li>1 mΩ ±0.5%, 100 mV at 100 A</li>
<li>10 W continuous rating in a solid alloy element</li>
<li>50 ppm/°C temperature coefficient</li>
<li>M4 bolt terminals for direct busbar mounting</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Battery and DC bus current measurement</li>
<li>Motor drive phase current sensing</li>
<li>Charger and power supply output monitoring</li>
<li>High-current protection thresholds</li>
</ul>
<h2>Selection note</h2>
<p>Route the sense pair as a twisted pair back to the amplifier and keep them away from the load current path. A few millimetres of shared copper in the sense return adds more error than the shunt tolerance allows.</p>
<h2>Ordering</h2>
<p>Send the current range, acceptable voltage drop, ambient temperature and mounting style. We confirm the resistance value and thermal derating, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/precision-shunt-1mohm-10w/">Precision Current Shunt, 1 mΩ, ±0.5%, 10 W, 4-Terminal</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Split-Core Current Transformer, 100 A / 50 mA, Class 1</title>
		<link>https://www.duomy.com/products/split-core-current-transformer-100a/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:29:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/split-core-current-transformer-100a/</guid>

					<description><![CDATA[<p>Split-core AC current transformer, 100 A primary to 50 mA secondary, class 1 accuracy, 50/60 Hz. Clamps around an existing cable without disconnecting it, for retrofit metering and load monitoring.</p>
<p>The post <a href="https://www.duomy.com/products/split-core-current-transformer-100a/">Split-Core Current Transformer, 100 A / 50 mA, Class 1</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A split-core transformer is installed around a cable that is already carrying current. The two halves clamp together, the magnetic circuit closes, and the load can be measured without shutting down the line. That installation advantage is the entire reason the part exists.</p>
<p>The output is a current, not a voltage, and it must never be left open-circuited while the primary carries current. An open secondary develops a high voltage across its own terminals and destroys the winding. Fit a burden resistor or a shorting terminal block before clamping it on.</p>
<h2>Key features</h2>
<ul>
<li>Clamps around existing cable, no disconnection required</li>
<li>100 A to 50 mA, 2000:1 ratio</li>
<li>Class 1 accuracy for billing-grade submetering</li>
<li>3 kV dielectric strength between primary and secondary</li>
<li>1 m flying leads, no separate terminal block</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Submetering and energy allocation</li>
<li>Pump and compressor load monitoring</li>
<li>Retrofit power measurement</li>
<li>Overcurrent and no-load detection</li>
</ul>
<h2>Selection note</h2>
<p>Never open the secondary while the primary is energised. Fit a burden resistor across the leads before installation, or use a shorting block, and only remove it after the primary is isolated.</p>
<h2>Ordering</h2>
<p>Send the cable diameter, primary current range and meter input type. We confirm ratio, burden and accuracy class, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/split-core-current-transformer-100a/">Split-Core Current Transformer, 100 A / 50 mA, Class 1</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Hall-Effect Current Sensor Module, 50 A, ±0.7%</title>
		<link>https://www.duomy.com/products/hall-current-sensor-50a/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:45 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/hall-current-sensor-50a/</guid>

					<description><![CDATA[<p>Closed-loop Hall-effect current sensor, 50 A nominal, ±0.7% accuracy, 0 to 5 V output, 12 to 24 V supply. Galvanically isolated current measurement for drives and inverters.</p>
<p>The post <a href="https://www.duomy.com/products/hall-current-sensor-50a/">Hall-Effect Current Sensor Module, 50 A, ±0.7%</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A closed-loop Hall current sensor measures the field around a primary conductor and drives a compensation winding to null it, which makes the output linear and largely independent of temperature. That is why it is used where a shunt would need isolation or would dissipate too much: motor phases, inverter legs, battery strings.</p>
<p>The through-hole primary is the point to design around. The conductor passes through the aperture, so the measurement is galvanically isolated and the sensor never sees the bus voltage. Two and a half kilovolts of isolation is enough for 400 V class equipment.</p>
<h2>Key features</h2>
<ul>
<li>Closed-loop compensation for linearity and low drift</li>
<li>50 A nominal, ±75 A measurement range</li>
<li>2,500 V AC galvanic isolation</li>
<li>100 kHz bandwidth, 5 µs response</li>
<li>0 to 5 V output referenced to 2.5 V at zero current</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Motor phase current measurement</li>
<li>Inverter and drive output monitoring</li>
<li>Battery string and DC bus current</li>
<li>Welding and plating power supplies</li>
</ul>
<h2>Selection note</h2>
<p>Array</p>
<h2>Ordering</h2>
<p>Send the nominal and peak current, bus voltage, bandwidth and output requirement. We confirm the range and isolation class, then quote with the connector option.</p>
<p>The post <a href="https://www.duomy.com/products/hall-current-sensor-50a/">Hall-Effect Current Sensor Module, 50 A, ±0.7%</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Linear Hall-Effect Sensor, 0.5–4.5 V Ratiometric, TO-92</title>
		<link>https://www.duomy.com/products/linear-hall-sensor-to92/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 20 Nov 2026 01:06:44 +0000</pubDate>
				<guid isPermaLink="false">https://www.duomy.com/products/linear-hall-sensor-to92/</guid>

					<description><![CDATA[<p>Ratiometric linear Hall-effect sensor in TO-92, 4.5 to 5.5 V supply, 0.5 to 4.5 V analogue output proportional to magnetic field. Position, current and angle measurement.</p>
<p>The post <a href="https://www.duomy.com/products/linear-hall-sensor-to92/">Linear Hall-Effect Sensor, 0.5–4.5 V Ratiometric, TO-92</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Overview</h2>
<p>A linear Hall sensor reports field strength as a voltage, which turns a magnet into a position encoder: the output rises and falls smoothly as the magnet approaches, and an ADC resolves the distance. A ratiometric output scales with the supply, so noise on the 5 V rail cancels when the ADC uses the same reference.</p>
<p>Two and a half millivolts per gauss across ±800 G gives a usable range for a magnet moving a few millimetres, and 1.5 mV of noise sets the resolution floor. Averaging several samples in firmware is usually cheaper than specifying a lower-noise part.</p>
<h2>Key features</h2>
<ul>
<li>Ratiometric analogue output, 0.5 to 4.5 V</li>
<li>2.5 mV/G sensitivity, ±800 G range</li>
<li>Zero-field output at mid-supply</li>
<li>TO-92 package for through-hole assembly</li>
<li>Linear response with no latching behaviour</li>
</ul>
<h2>Typical applications</h2>
<ul>
<li>Non-contact position measurement</li>
<li>Throttle and pedal position sensing</li>
<li>Current measurement with a concentrator core</li>
<li>Angle measurement with a diametric magnet</li>
</ul>
<h2>Selection note</h2>
<p>Keep the sensor away from stray fields such as motor magnets and current-carrying conductors. A linear sensor reports every field in the area, not only the one the design intends.</p>
<h2>Ordering</h2>
<p>Send the measurement range, required resolution, supply voltage and magnet arrangement. We confirm sensitivity and linearity over the travel, then quote.</p>
<p>The post <a href="https://www.duomy.com/products/linear-hall-sensor-to92/">Linear Hall-Effect Sensor, 0.5–4.5 V Ratiometric, TO-92</a> appeared first on <a href="https://www.duomy.com">DuoMy Sensing</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>