DM-HALL-L1-SOT23
Ask about this product
Send your application details and get a specification answer within one business day.
Hall-Effect Current Sensor Module, 50 A, ±0.7%
Closed-loop Hall-effect current sensor, 50 A nominal, ±0.7% accuracy, 0 to 5 V output, 12 to 24 V supply. Galvanically isolated current measurement for drives and inverters.
| Parameter | Value | Unit |
|---|---|---|
| Nominal current | 50 | A |
| Measurement range | ±75 | A |
| Accuracy | ±0.7 | % of nominal at 25 °C |
| Output | 0 to 5 V, 2.5 V at zero current | |
| Supply voltage | 12 to 24 | V DC |
| Isolation voltage | 2,500 | V AC, 1 min |
| Bandwidth | 0 to 100 | kHz |
| Response time | 5 | µs |
| Primary conductor | Through-hole, 10 mm | mm |
| Operating temperature | −40 to +85 | °C |
Overview
A closed-loop Hall current sensor measures the field around a primary conductor and drives a compensation winding to null it, which makes the output linear and largely independent of temperature. That is why it is used where a shunt would need isolation or would dissipate too much: motor phases, inverter legs, battery strings.
The through-hole primary is the point to design around. The conductor passes through the aperture, so the measurement is galvanically isolated and the sensor never sees the bus voltage. Two and a half kilovolts of isolation is enough for 400 V class equipment.
Key features
- Closed-loop compensation for linearity and low drift
- 50 A nominal, ±75 A measurement range
- 2,500 V AC galvanic isolation
- 100 kHz bandwidth, 5 µs response
- 0 to 5 V output referenced to 2.5 V at zero current
Typical applications
- Motor phase current measurement
- Inverter and drive output monitoring
- Battery string and DC bus current
- Welding and plating power supplies
Selection note
Array
Ordering
Send the nominal and peak current, bus voltage, bandwidth and output requirement. We confirm the range and isolation class, then quote with the connector option.
No documents attached yet.
Request documentation →Related products
View allDM-HALL-A1-TO92
Linear Hall-Effect Sensor, 0.5–4.5 V Ratiometric, TO-92
DM-HALL-U1-SOT23