DM-IF-ISO-2CH-50M
Ask about this product
Send your application details and get a specification answer within one business day.
CAN FD Transceiver, 5 Mbps, 5 V, SO-8
CAN FD transceiver, 5 Mbps, 5 V supply, ±58 V bus fault protection, SO-8. Physical layer for CAN and CAN FD networks in vehicles and industrial machinery.
| Parameter | Value | Unit |
|---|---|---|
| Interface | CAN FD, ISO 11898-2 | |
| Data rate | 5 | Mbps |
| Supply voltage | 4.5 to 5.5 | V |
| Bus fault protection | ±58 | V |
| Bus pins ESD | ±8 | kV human body model |
| Common-mode range | −12 to +12 | V |
| Loop delay | 70 | ns typical |
| Standby current | 10 | µA |
| Package | SO-8 | |
| Operating temperature | −40 to +125 | °C |
Overview
The transceiver is the physical layer: it turns the controller TX and RX logic levels into the differential bus and back. Five megabits is the CAN FD data-phase rate, and the loop delay of 70 ns is part of the timing budget that decides whether the sample point stays valid at that rate.
Bus fault protection of ±58 V is what makes the part survive a short to a 24 V rail or a reversed connection on a service cable. Without it, a single wiring error during commissioning destroys the transceiver and possibly the controller behind it.
Key features
- CAN FD capable, 5 Mbps data phase
- ±58 V bus fault protection
- Loop delay 70 ns for stable sampling
- 10 µA standby current
- SO-8 package, standard pinout
Typical applications
- Automotive and off-highway networks
- Industrial machinery buses
- Battery management systems
- Charger and inverter communication
Selection note
Terminate with 120 Ω at each end of the bus and keep the stub length short. At 5 Mbps a 30 cm stub is enough to corrupt the frame at the sample point.
Ordering
Send the bus rate, node count, supply and fault exposure. We confirm the protection level and loop delay, then quote.
No documents attached yet.
Request documentation →Related products
View allDM-IF-RS485-20M
RS-485 Transceiver, 3.3 V, 20 Mbps, ±15 kV ESD, SO-8
DM-IF-RS232-2CH