Industry Application

Sensors for Oil & Gas and Hazardous Areas

Pressure, level and flow instrumentation for Zone 0, Zone 1 and Zone 2 areas, with the certification documents the site and the insurer will ask for.

Zone 0 to Zone 2 certified Ex ia / Ex d
Maximum process pressure 1,000 bar
NACE-compliant wetted parts Sour service

Hazardous-area instrumentation is a documentation exercise as much as a measurement one. The sensor, the barrier or isolator and the cable all have their own certification, and the installation is only compliant if the entity parameters match across the loop. A transmitter with the right accuracy and the wrong certificate cannot be installed at all.

Our oil and gas range covers Ex ia and Ex d pressure transmitters for wellhead, pipeline and process duty, radar level transmitters for tank farms and separators, and isolating signal conditioners that include the intrinsic safety barrier in the same DIN-rail module. Every certificate is supplied with the instrument, and the entity parameters are printed on the label as well as the datasheet.

For upstream and midstream applications we also supply high-pressure transmitters to 1,000 bar, corrosion-resistant wetted parts for sour service, and remote-seal diaphragm assemblies for viscous and high-temperature media where a direct mount would not survive.

Application Reality

What actually goes wrong here

These are the failure modes we are called in to solve, and the specification change that addresses each one.

Matching entity parameters across the loop

A certified transmitter connected through an uncertified barrier is a non-compliant installation. We supply the barrier, the transmitter and the loop calculation as one package.

Sour service and corrosion

H₂S-bearing media attack standard 316L. Wetted parts in compliance with NACE MR0175 are specified for sour wells and wet gas pipelines.

Viscous and high-temperature media

Direct-mounted transmitters clog or overheat. Remote-seal diaphragm assemblies move the sensing element away from the process and allow flushing.

Tank farm inventory accuracy

Custody transfer and inventory reconciliation need better than 3 mm. 80 GHz radar with a stilling well gives that, and it does not touch the product.

Site documentation

Commissioning teams need certificates, nameplate photographs and loop drawings at handover. We ship a documentation pack per instrument with the shipment.

Products

Specified for oil & gas applications

All products

Standards

What the audit will ask for

Standard Requirement
ATEX 2014/34/EU Equipment certification for explosive atmospheres
IECEx International hazardous-area certification
NACE MR0175 / ISO 15156 Sour service material compliance
IEC 61508 SIL 2 Functional safety capability

Application Example

Separator level control, onshore field

Situation

A producer was tripping the separator on high level two or three times a month because the existing guided-wave probe was blinded by wax and sand build-up.

What we changed

The contact probe was replaced with an 80 GHz radar transmitter on a 100 mm nozzle, configured with a build-up suppression algorithm and a narrow 4° beam that avoided the internal baffle.

Result

Level trips stopped over a nine-month observation period, and the same transmitter was specified for four additional separators at the site.

FAQ

Oil & Gas instrumentation questions

Can I install a Zone 1 transmitter with an existing barrier?

Only if the barrier's entity parameters (Uo, Io, Po, Co, Lo) are compatible with the transmitter's input parameters (Ui, Ii, Pi, Ci, Li) and the cable capacitance and inductance stay within the allowed values. We will run the calculation for you if you provide the barrier model.

Do you supply Ex d as well as Ex ia?

Yes. Ex ia is used where intrinsic safety suits the loop and the panel has barriers; Ex d flameproof is used for high-power or non-intrinsically-safe circuits. The two versions share the process connection envelope.

What is the maximum pressure rating available?

Standard transmitters reach 1,000 bar in 316L. Above that, we supply custom capsules to 1,500 bar for wellhead applications, with lead times of 6-8 weeks.

Are your instruments suitable for sour service?

Wetted parts are available in NACE MR0175 compliant materials, typically 316L with a defined hardness limit or duplex 2205 for higher chloride levels. State the H₂S partial pressure and the chloride concentration when you enquire.

What documentation comes with a hazardous-area order?

Each instrument ships with its certificate of conformity, the nameplate data, the entity parameter sheet or the Ex d schedule, and installation instructions. A loop drawing pack is available for projects that need it at handover.

Other industries

Send the application details and get a specification back within one business day.