Sensors & Modules

Humidity & Temperature Sensors

Digital and analogue RH sensors, from board-level DFN packages to cabled probes, for measuring 0-100% RH between -40 and +125 °C.

5 variants 4 catalogue items I²C, ±2% RH ±1.5% RH analogue / PWM

Need a specific part?

Send the part number, quantity and target price. We come back with availability, cross-references and the datasheet.

Request a quote Ask an engineer

Lead timeQuoted per line

MOQBy line item

Cross-referenceOn request

Humidity is the measurement where the datasheet accuracy and the installed accuracy diverge most. A sensor specified at ±2% RH is tested in a clean calibration chamber; mounted next to a dusty fan, or in a housing that traps condensation, the same part drifts several percent within a year and nobody notices because there is no second reference.

The sensing element is almost always a capacitive polymer layer whose dielectric constant changes with absorbed water. That mechanism is inherently sensitive to contamination, to condensation and to prolonged exposure at the top of the range. The electronics around it — a bandgap temperature sensor, an ADC and a calibration memory — are what make a modern digital part accurate, not the polymer alone.

We supply board-level digital sensors for volume products, cabled probes for equipment where the measurement point is remote from the electronics, and higher-accuracy parts for cleanrooms and drying processes where a percentage point changes the outcome. The filter membrane and the mounting location matter more than the accuracy class in most installations.

Range Overview

Humidity & Temperature Sensors variants

Each variant exists because a different circuit position asks for something different: voltage, current, package and stability trade against each other.

Digital RH + temperature module

I²C, ±2% RH

Calibrated capacitive element with an I²C interface, factory linearised and temperature compensated. The default for new designs.

High-accuracy digital

±1.5% RH

Tighter calibration and lower drift, used in cleanrooms, drying ovens and reference instruments.

Analogue output sensor

analogue / PWM

Ratiometric voltage or PWM output, for designs without a digital bus or where the sensor sits at the end of a long cable.

Cabled probe / transmitter

remote measurement

Sensor element on a cable or in a sintered filter housing, with 4-20 mA, Modbus or IO-Link output for building and process systems.

Condensation-resistant variant

wet environments

Protective membrane or a heated element that drives off condensation after a cold start, for outdoor and washdown equipment.

Catalogue

Humidity & Temperature Sensors — quoted on request

Browse all products

Technical Range

Typical specifications

Figures below are the range across the family, not a single model. Specify the exact range, accuracy and connection on the quote request and we will confirm which variant meets it.

Request a specification check
Parameter Typical
RH range 0 to 100% RH
RH accuracy ±1.5% to ±3% RH
Temperature range -40 to +125 °C
Temperature accuracy ±0.2 to ±0.5 °C
Resolution 0.01% RH / 0.01 °C
Long-term drift < 0.5% RH per year
Response time 8 to 30 s (63%)
Output / supply I²C, analogue, PWM / 2.4-5.5 V

Applications

Where this family is used

HVAC and building control

Duct and room sensors for ventilation control, where long-term stability matters more than absolute accuracy.

Cleanrooms and pharmaceutical storage

Tight-tolerance measurement with documented calibration, where a percentage point is a compliance issue.

Drying and curing equipment

High-humidity and high-temperature duty, where the sensor must survive conditions near the top of its range.

Greenhouses and cold storage

Condensation-prone environments that need a protected element and a heated or membrane-covered variant.

Selection Guide

How to specify correctly

  1. 1

    Read the accuracy band, not the headline figure

    ±2% RH is usually specified between 20 and 80% RH at 25 °C. Outside that band the error grows, and near 100% RH condensation makes any capacitive measurement unreliable until the element dries.

  2. 2

    Design the airflow, not just the hole

    The sensor measures the air that reaches it. A housing with a small opening and no airflow reads the temperature of the enclosure wall, not the process. A sintered filter gives both protection and a defined diffusion path.

  3. 3

    Keep the sensor away from heat sources

    A regulator dissipating half a watt next to the sensor raises the local temperature by several degrees and lowers the reported RH, because RH is relative to the local temperature, not the ambient.

  4. 4

    Plan for condensation recovery

    After condensation the element needs time and heat to return to a valid reading. A heated variant or a firmware delay before the first valid sample prevents the controller from acting on a wet sensor.

  5. 5

    Set a recalibration interval from the drift spec

    At 0.5% RH per year, a ±2% sensor leaves the tolerance band in about three years. For regulated environments, plan a replacement or a calibration check at that point rather than waiting for a complaint.

FAQ

Humidity & Temperature Sensors questions

Why does a humidity sensor drift over time?

The polymer layer absorbs contaminants from the air — dust, oils, volatile organic compounds — which change its water uptake behaviour. The drift is usually downward at high humidity and is not reversible by cleaning. Filters slow it, and recalibration or replacement is the only correction.

Capacitive or resistive sensing element?

Capacitive dominates modern designs because it is linear, stable and tolerant of condensation recovery. Resistive elements are cheaper but non-linear and more sensitive to contamination. Almost every digital RH sensor on the market is capacitive.

Can a sensor recover after condensation?

Usually yes, once the element dries. While wet, the reading is meaningless because the water film short-circuits the measurement. A heated sensor or a firmware delay avoids acting on the invalid period, and a hydrophobic membrane reduces how often it happens.

Do I need to calibrate the sensor in the field?

Not the electronics, which are factory calibrated. What drifts is the sensing element, and that cannot be corrected by a single-point offset in most cases. For regulated applications, replace the sensor at the interval implied by the drift specification, or verify against a reference at two humidity points.

Why does my sensor read higher humidity than the weather report?

Because it is measuring where it is installed. RH is relative to local temperature, so a sensor in a cooler corner of a room reads higher than the outside air, and one near a heater reads lower. The weather report is also for a different location and a different time.

Related categories