Sensors & Modules

Hall Effect Sensors

Magnetic sensors that detect a field without contact, for rotation counting, end-of-travel detection and isolated current measurement.

5 variants 4 catalogue items Bop 1.5-40 mT alternating poles either pole

Need a specific part?

Send the part number, quantity and target price. We come back with availability, cross-references and the datasheet.

Request a quote Ask an engineer

Lead timeQuoted per line

MOQBy line item

Cross-referenceOn request

A Hall sensor converts a magnetic field into a digital or analogue output, which makes it the standard way to detect position or rotation through a sealed wall. Nothing wears, nothing enters the enclosure, and the sensing distance is set by the magnet rather than the mechanism. The specification that decides whether it works is not sensitivity in the abstract but the field the magnet actually produces at the sensor, across temperature and air gap.

The three families behave differently enough that choosing the wrong one is a common error. A unipolar switch turns on in one field polarity and off when the field drops, which suits a single end-of-travel target. A bipolar latch requires a polarity reversal to change state, which is what makes it usable for counting gear teeth or a multipole ring. A linear sensor outputs a voltage proportional to the field, for angle and current measurement.

We supply digital switches and latches for position and speed, linear ratiometric parts for angle and current, and automotive-qualified versions where the sensor sits in a harness exposed to load dump and thermal cycling.

Range Overview

Hall-Effect Sensors variants

Each variant exists because a different circuit position asks for something different: voltage, current, package and stability trade against each other.

Unipolar switch

Bop 1.5-40 mT

Turns on above a defined field from one pole and off when the field falls below a lower threshold. For end-of-travel and presence detection with a single magnet.

Bipolar latch

alternating poles

Needs a south pole to turn on and a north pole to turn off, so it holds state across a slow field change. The basis of rotation counting and BLDC commutation.

Omnipolar switch

either pole

Responds to either polarity, turning on in the presence of any field above the threshold. Simplifies magnet orientation in assembly.

Linear / ratiometric

analogue out

Analogue output proportional to field strength, used for angle sensing with a rotating magnet and for contactless current measurement.

Current sensor IC

isolated current

Hall element with a magnetic concentrator integrated in the package, placed over a PCB trace to measure current without breaking the circuit.

Catalogue

Hall-Effect Sensors — quoted on request

Browse all products

Technical Range

Typical specifications

Figures below are the range across the family, not a single model. Specify the exact range, accuracy and connection on the quote request and we will confirm which variant meets it.

Request a specification check
Parameter Typical
Operate point Bop 1.5 mT to 40 mT
Release point Brp Bop minus 1-15 mT
Supply voltage 2.5 V to 24 V
Output type Open-drain, push-pull, analogue
Output current 5 mA to 25 mA
Operating temperature -40 to +150 °C
Chopper stabilisation Yes on precision parts
Packages SOT-23, SIP-3, TO-92, DFN

Applications

Where this family is used

Rotation and speed sensing

A latch counting teeth on a gear or poles on a magnetic ring, giving speed and direction without an encoder.

End-of-travel and position

A switch detecting a magnet in a cylinder, valve or door, with no mechanical contact and no seal to wear.

BLDC commutation

Three latches or a single linear part resolving rotor position for electronic commutation in fans and pumps.

Isolated current measurement

A current sensor IC over a PCB trace, or a linear part with a concentrator, measuring current without a shunt in the circuit.

Selection Guide

How to specify correctly

  1. 1

    Calculate the field at the sensor, not the magnet grade

    Magnet strength falls roughly with the cube of distance and linearly with temperature. A N35 magnet that gives 30 mT at 2 mm may give 8 mT at 6 mm and 5 mT at 100 °C, which is below the operate point of a part chosen on the 25 °C curve.

  2. 2

    Use a latch for counting, a switch for presence

    A unipolar switch releases as soon as the field drops, so it produces two edges per revolution on a multipole ring and cannot resolve direction. A latch holds state until the polarity reverses, which is what makes a clean square wave.

  3. 3

    Check hysteresis against the mechanical speed

    Too little hysteresis and the output chatters at a slow edge; too much and the release point is far from the operate point, shifting the effective switching position. For slow mechanisms choose a part with a wide Brp-Bop window.

  4. 4

    Keep the supply and output traces short

    The output is a small current switching against a pull-up; a long unshielded cable picks up motor noise and produces false counts. Route away from motor phases and add an RC filter at the receiving end.

  5. 5

    Budget supply headroom for open-drain parts

    An open-drain output pulls down to ground and needs a pull-up to a supply the receiving circuit can accept. With a 24 V industrial input, a 3.3 V pull-up will not register, and a 24 V pull-up may exceed the sensor rating.

FAQ

Hall-Effect Sensors questions

What is the difference between a Hall switch and a Hall latch?

A switch turns on in the presence of a field of the correct polarity and off when the field drops below the release point. A latch needs the opposite polarity to change state, so it remembers its last state. Switches detect presence; latches count rotation and resolve direction.

How strong a magnet do I need?

Enough to exceed the operate point at the maximum air gap and the maximum operating temperature. Work backwards: choose the gap from the mechanical design, find the field that the candidate magnet produces at that gap at 100 °C, and pick a sensor whose Bop is at least 30% below that figure.

Why does my Hall output chatter?

Either the field is hovering near the operate point, or the hysteresis is smaller than the mechanical jitter, or the output trace is picking up switching noise. Check the field margin first, then the hysteresis window, then the routing and filtering.

Can a Hall sensor detect a ferrous gear without a magnet?

Not a passive one. A Hall element needs a field to measure. For a steel target you need a back-bias magnet behind the sensor so the gear teeth modulate the field, or a different technology such as a variable reluctance or magnetoresistive sensor.

Hall or magnetoresistive for position sensing?

Hall is cheaper, well understood and adequate for on-off detection and moderate-resolution angle measurement. Magnetoresistive sensors give higher sensitivity and better angular resolution in a smaller field, at higher cost, and are the better choice for precise angular encoders.

Related categories

Tell us the application and we will confirm the right variant.