The first decision in any power tree is linear or switching, and it is usually made on efficiency without checking what the load actually needs. An LDO is 40% efficient dropping 24 V to 3.3 V, which is unacceptable at one amp and irrelevant at twenty milliamps. A buck converter is 90% efficient at any current but brings switching noise that an analogue front end may not tolerate.
The second decision is where the noise matters. An LDO rejects input ripple by 60 to 90 dB at low frequency, falling to 40 dB or less above 100 kHz. A buck converter puts its ripple at the switching frequency and its harmonics, which the LDO downstream can remove only if its rejection at that frequency is adequate. Cascading a buck into an LDO is the standard way to get both efficiency and a clean rail.
We supply the discrete regulators and the integrated PMICs that cover both patterns, from single LDOs in SOT-23 to multi-rail devices with sequenced outputs. The selection comes down to input range, dropout, quiescent current, thermal path and the transient the load will demand.
Range Overview
Power Management ICs variants
Each variant exists because a different circuit position asks for something different: voltage, current, package and stability trade against each other.
LDO regulator
60-90 dB PSRRLinear regulator with low dropout and high ripple rejection. No switching noise, few external parts, but efficiency set by the input-output ratio.
Synchronous buck
85-95% efficientIntegrated high-side and low-side FETs with an inductor and two capacitors. The default for any rail above a few hundred milliamps.
Boost and buck-boost
wide VinStep-up and four-switch topologies for battery equipment where the input crosses the output voltage.
Integrated PMIC
sequenced railsThree to eight rails in one package with power sequencing, used on processors, FPGAs and camera modules where board area is critical.
Charge pump / inverting
no inductorSwitched-capacitor converters for low-current negative or doubled rails, where an inductor will not fit.
Catalogue
Power Management ICs — quoted on request
DM-PMIC-LSW-DUAL-2A
Dual-Channel Load Switch, 5.5 V 2 A, DFN-8
DM-PMIC-BUCK-3A-36V
36 V 3 A Synchronous Buck Converter, DFN-10
DM-PMIC-BUCK-5A-18V
5 A 18 V Synchronous Buck Converter, SO-8EP
Technical Range
Typical specifications
Figures below are the range across the family, not a single model. Specify the exact range, accuracy and connection on the quote request and we will confirm which variant meets it.
Request a specification check| Parameter | Typical |
|---|---|
| Input voltage | 1.8 V to 36 V |
| Output voltage | 0.6 V to 24 V |
| Output current | 0.1 A to 20 A |
| Dropout (LDO) | 60 mV to 500 mV |
| PSRR (LDO) | 60-90 dB at 1 kHz |
| Quiescent current | 1 µA to 5 mA |
| Switching frequency | 500 kHz to 3 MHz |
| Packages | SOT-23, DFN 2×2, SO-8, QFN, TO-263 |
Applications
Where this family is used
Analogue and sensor front ends
Clean rails for ADCs, op-amps and bridge sensors, where switching ripple couples directly into the measurement.
Processor and FPGA multi-rail supplies
Core, I/O and auxiliary rails with defined power-up order, usually from a PMIC with sequencing built in.
Battery-powered instruments
Nanopower LDOs and high-efficiency bucks where quiescent current decides standby life.
Industrial 24 V to logic conversion
Wide-input buck stages that survive the transients on a 24 V factory rail and deliver 5 V or 3.3 V downstream.
Selection Guide
How to specify correctly
-
1
Calculate LDO dissipation before choosing it
Power is (Vin - Vout) × I. Dropping 24 V to 3.3 V at 200 mA means 4.1 W in a SOT-23, which no package can dissipate. Above about 0.5 W, move to a switching stage.
-
2
Read PSRR at the ripple frequency
The headline 80 dB is quoted at 1 kHz. A buck switching at 500 kHz needs the rejection at 500 kHz and at its harmonics, where the same part may only manage 30 dB.
-
3
Check the DC-DC external component budget
An integrated converter still needs an inductor, an output capacitor and usually a feedforward capacitor for loop stability. Small packages often demand specific component values, not just any 10 µH part.
-
4
Design the thermal pad first
Most modern regulators dissipate through the exposed pad into the copper beneath. A pad without vias to an inner layer has a thermal resistance several times the datasheet figure.
-
5
Confirm start-up and protection behaviour
Soft-start time, current limit, thermal shutdown and undervoltage lockout determine whether the rail survives a hot-plug or a shorted load. Check them against the fault the system will actually see.
Used in these industries
All industries →FAQ
Power Management ICs questions
When should I use an LDO instead of a buck converter?
When the current is low, the input-output difference is small, or the load cannot tolerate switching noise. Below roughly 100 mA and 1 V of headroom, an LDO is simpler and often cheaper. Above that, the dissipation makes a switching stage the only practical option, even if a second LDO is needed downstream for noise.
What does dropout voltage actually mean?
The minimum input-output difference at which the regulator can still hold regulation at rated current. If an LDO has 300 mV dropout and delivers 3.3 V, the input must stay above 3.6 V. Below that the output follows the input minus the dropout, which is why battery equipment needs to check the end-of-discharge voltage.
How do I use the PSRR figure?
Find the rejection at the frequency of the ripple you are trying to remove, then subtract it from the input ripple amplitude. A 100 mV ripple at 500 kHz with 30 dB rejection leaves 3 mV at the output. The headline low-frequency figure is rarely the one that matters in a switching supply.
Why does my buck converter output have ripple at the switching frequency?
The inductor current ramps between two values, and the output capacitor converts that ramp into a voltage ripple through its ESR and capacitance. Reducing ripple means more inductance, more output capacitance, lower ESR, or a higher switching frequency. The ESR term usually dominates with electrolytic output capacitors.
How do I set the output voltage on an adjustable regulator?
With a resistor divider from output to the feedback pin to ground, sized by the internal reference voltage. Keep the divider current at least a hundred times the feedback bias current, and route the feedback trace away from the inductor and switch node to avoid injecting switching noise into the control loop.