A terminal block is the one component the end user touches with a screwdriver, which makes it the one most likely to be damaged in the field. The electrical specification — pitch, current, voltage — is easy to compare across datasheets. The mechanical behaviour under a stripped wire, an over-torqued screw or a vibrating panel is not, and that is where failures come from.

The termination style decides the maintenance profile. Screw clamps tolerate large wire ranges and field rework, but they loosen under vibration and the torque depends on who is holding the driver. Spring-cage terminals hold force constant and survive vibration, but need a specific strip length and a tool to open. Push-in terminals are the fastest to wire and the most sensitive to wire preparation.

We supply the pitch range that covers control boards from 2.54 mm signal headers to 10.16 mm power entry, in all three termination styles, with pluggable versions where the board has to be removable without unwiring the panel.

Range Overview

Terminal Blocks variants

Each variant exists because a different circuit position asks for something different: voltage, current, package and stability trade against each other.

Screw clamp

to 57 A

The classic rising-cage terminal: wide wire range, high current capability and tolerance for imperfect wire preparation, at the cost of torque consistency.

Spring cage

vibration proof

A spring holds the wire against a busbar. Constant force, vibration resistant and no torque to check, but a tool is needed to release the wire.

Push-in

fast wiring

Solid or ferruled wire pushes directly into a spring contact. Fastest to wire, and the least forgiving of a nicked or twisted conductor.

Pluggable (header + plug)

serviceable

A board header with a removable plug, so a module can be swapped without disturbing the field wiring. Two contacts per position, so derate accordingly.

Barrier strip

high isolation

Individual screw positions separated by barriers, used on power distribution and legacy equipment where creepage between poles must be large.

Catalogue

Terminal Blocks — quoted on request

Browse all products

Technical Range

Typical specifications

Figures below are the range across the family, not a single model. Specify the exact range, accuracy and connection on the quote request and we will confirm which variant meets it.

Request a specification check
Parameter Typical
Pitch 2.54 / 3.5 / 3.81 / 5.0 / 5.08 / 7.5 / 10.16 mm
Poles 2 to 24
Wire range 0.08 to 6 mm² (AWG 28-10)
Rated current 4 A to 57 A
Rated voltage 150 V to 1,000 V
Stripping length 6 to 10 mm
Screw torque 0.2 to 1.2 N·m
Connection cycles 10 to 50

Applications

Where this family is used

Control cabinet wiring

The interface between a PCB and field cable in industrial panels, where the installer brings prepared wire and expects it to hold.

I/O modules and PLC slices

Pluggable headers that let a channel card be replaced without unwiring the terminal strip.

Power entry on drivers and supplies

Wider pitch terminals carrying mains or 48 V DC at several amps, with barriers between poles.

Sensor and actuator junction points

Small-pitch spring terminals in junction boxes, where vibration and moisture are the dominant stressors.

Selection Guide

How to specify correctly

  1. 1

    Derive voltage rating from pitch, not from the label

    A 3.5 mm pitch part cannot achieve the isolation of a 7.5 mm part regardless of what the plastics are made from. Check the rated voltage against the working voltage and the pollution degree of the installation.

  2. 2

    Choose the termination by who wires it

    Factory wiring with prepared ferrules suits push-in. Field wiring by an installer with a screwdriver suits screw clamp. Anything that vibrates or is wired once and forgotten suits spring cage.

  3. 3

    Check the wire range at both ends

    A terminal rated for 0.08-2.5 mm² will not reliably clamp a 0.5 mm² stranded wire without a ferrule, and will not accept a 4 mm² at all. Specify ferrules where stranded wire is used.

  4. 4

    Allow for interlocking and keying

    Multi-pole assemblies are built from single sections that slide together. Mixed pitches do not interlock, and colour coding only helps if the code is visible after installation.

  5. 5

    Respect torque and strip length as a process

    Torque and strip length belong in the work instruction, not in the installer’s judgement. A calibrated driver and a strip gauge turn two common failure modes into non-events.

FAQ

Terminal Blocks questions

Do spring-cage terminals loosen over time?

No. The spring maintains roughly constant force over its rated life, which is why spring terminals are preferred in high-vibration applications and why they do not need a re-torque check. The failure mode is different: a wire that was inserted without the correct strip length sits on insulation and pulls out under load.

Why is the rated voltage of a small-pitch terminal so low?

The rating follows creepage and clearance distances, which are set by the pitch. A 3.5 mm pitch part has less than half the surface distance between poles of a 7.5 mm part, so its rated voltage is lower even though the plastic is the same. Using a small-pitch part at mains voltage is a design error, not a documentation issue.

Can I clamp stranded wire directly without a ferrule?

On screw clamps it usually works but the strands spread and a few can escape the clamp, reducing the effective cross-section. On spring-cage and push-in terminals a bare stranded wire is a reliability risk. Use a ferrule crimped with the correct die for any stranded conductor.

What torque should I use?

The value on the datasheet, applied with a calibrated driver. Under-torque leaves high resistance that heats under load; over-torque cracks the housing and can shear the clamping cage. Most 5 mm pitch terminals sit between 0.4 and 0.6 N·m.

Pluggable or fixed terminal for a serviceable module?

Pluggable, if the module is expected to be replaced in the field. The trade-off is that each position now has two contact interfaces instead of one, so the current rating drops and there is one more point that can corrode. Where the module is never removed, a fixed terminal is more reliable.