Passive Components

Aluminium Electrolytic Capacitors

Bulk storage and ripple filtering from 0.1 µF to 100,000 µF, in radial, SMD and snap-in packages rated to +105 °C or +125 °C.

5 variants 4 catalogue items 2,000-10,000 h automated assembly up to 6 A ripple

Need a specific part?

Send the part number, quantity and target price. We come back with availability, cross-references and the datasheet.

Request a quote Ask an engineer

Lead timeQuoted per line

MOQBy line item

Cross-referenceOn request

An electrolytic capacitor is the only common component whose lifetime is specified rather than assumed. The datasheet life figure — typically 2,000 to 12,000 hours — is quoted at rated voltage and maximum category temperature, and every ten degrees below that roughly doubles the expected life. A supply that runs its electrolytics at 105 °C will need them replaced; the same supply running at 75 °C will outlast the equipment.

The practical selection problem is that life, ripple current and ESR are coupled. A low-ESR part handles more ripple without self-heating, which extends life, but low-ESR parts are physically larger and cost more. A high-capacitance part in the same can has thinner foil and a lower ripple rating. You cannot maximise all three in one package, so the design has to state which one the application actually needs.

We supply the three package families that cover most industrial boards: radial leaded for through-hole assembly, SMD V-chip for automated lines, and snap-in or screw terminal for the bulk position on power supplies and motor drives. Polymer hybrid parts are available where the ripple current or the low-temperature ESR would otherwise force a much larger can.

Range Overview

Aluminium Electrolytic Capacitors variants

Each variant exists because a different circuit position asks for something different: voltage, current, package and stability trade against each other.

Radial leaded

2,000-10,000 h

Through-hole cans from 4 mm to 18 mm diameter, the default for industrial control boards and prototypes where hand assembly is acceptable.

SMD V-chip

automated assembly

Surface-mount base plate for reflow assembly, with low profile for boards that sit under a lid or inside a DIN enclosure.

Snap-in / screw terminal

up to 6 A ripple

Large can devices for DC-link and input bulk positions, with ripple current ratings in the multi-amp range.

Polymer hybrid

low ESR

Conductive polymer plus liquid electrolyte: low ESR at low temperature, higher ripple capability and no dry-out failure mode at end of life.

Long-life series

10,000 h+

105 °C parts rated 10,000-12,000 hours, used where the capacitor is not serviceable after installation.

Catalogue

Aluminium Electrolytic Capacitors — quoted on request

Browse all products

Technical Range

Typical specifications

Figures below are the range across the family, not a single model. Specify the exact range, accuracy and connection on the quote request and we will confirm which variant meets it.

Request a specification check
Parameter Typical
Capacitance 0.1 µF to 100,000 µF
Voltage 6.3 V to 500 V DC
Endurance 2,000 h to 12,000 h at 105 °C
Ripple current 30 mA to 6 A at 100 kHz / 105 °C
ESR 20 mΩ to 5 Ω
Capacitance tolerance ±20% (M)
Temperature range -40 to +105 °C
Case sizes 4×5 mm to 35×50 mm

Applications

Where this family is used

Input bulk and hold-up

Stores energy across the rectified mains cycle so the downstream converter sees a stable DC bus, and provides ride-through for short dips.

Output ripple filtering

Absorbs the switching ripple that the inductor cannot remove, in LED drivers, chargers and DC-DC modules.

Motor drive DC link

Snap-in and screw terminal banks handle the pulsed current of inverter bridges and absorb regenerative energy.

Audio and instrumentation smoothing

Large capacitance with moderate ESR, where the requirement is a low-frequency pole rather than high-frequency impedance.

Selection Guide

How to specify correctly

  1. 1

    Size ripple current at the actual switching frequency

    The catalogue figure is quoted at 100 kHz. At 50 Hz or 120 Hz the allowable ripple drops sharply, and the correction factor table on the datasheet is not optional. Use the frequency of the current the part will really see.

  2. 2

    Calculate life at the real ambient temperature

    Life = rated life × 2^((Tmax - Ta)/10) × voltage factor. A 105 °C 5,000 h part at 65 °C gives roughly 80,000 hours; the same part at 95 °C gives 10,000. Design to the enclosure temperature measured with the lid on.

  3. 3

    Check ESR at the cold start condition

    Electrolyte viscosity rises as temperature falls, and ESR can multiply by ten at -40 °C. Equipment that must start cold needs either a polymer hybrid part or a soft-start that limits the initial ripple.

  4. 4

    Leave vent clearance and observe polarity

    The vent is a pressure relief, not decoration. Keep it clear of the enclosure wall, and make sure the silkscreen polarity mark survives assembly, because a reversed electrolytic fails short and vents.

  5. 5

    Watch the sleeve on long-life series

    Counterfeit and re-sleeved capacitors are common in long-life series, where the outer sleeve carries the rating. Buy through traceable distribution and check the date code against the shipment.

FAQ

Aluminium Electrolytic Capacitors questions

How is electrolytic capacitor life calculated?

The standard formula is L = L0 × 2^((Tmax - Ta)/10) × K, where L0 is the rated endurance, Tmax the category temperature, Ta the ambient at the capacitor and K a voltage derating factor between 0.7 and 1.0. It is an estimate of the time for capacitance to drop 20% or ESR to double, not a guarantee, so most designs apply a further safety factor of two.

Can I replace a 105 °C part with an 85 °C part?

Only if the ambient at the capacitor is comfortably below 85 °C and the ripple current de-rating works out. In practice a 105 °C part in a 70 °C enclosure has four times the life of an 85 °C part in the same place, so the 85 °C substitution usually shortens service life. It is rarely the saving it looks like.

What causes the top of a capacitor to bulge?

Gas generation from electrolyte breakdown, driven by overvoltage, reverse polarity, excessive ripple heating or a dried-out electrolyte after end of life. Bulging is a late symptom: by the time the vent lifts, capacitance has usually fallen well below tolerance. Replace the whole bank, not just the failed can.

When should I use polymer hybrid instead of liquid electrolytic?

When the ripple current is high relative to the can size, when the equipment must start at -40 °C, or when a dry-out failure mode is unacceptable. Polymer hybrid parts have lower ESR and a safer end of life, but they cost more and are limited in the highest voltage ratings.

Why does the capacitance drop at low temperature?

The electrolyte conductivity falls as temperature falls, which raises ESR and reduces the effective capacitance at the measurement frequency. A part measured at 100 Hz and -40 °C can read 20-30% low. It is not a defect; it is a property of the chemistry, and it is why cold-start ripple must be checked separately.